FlowJam A –
Material flow monitoring
for hose lines
The hose line is inserted into the sensor for measuring.
What do you want to do?
Use
the detection area.
The detection is independent of the direction of flow through the Doppler effect evaluation system.
The flow of material through non-metallic pipelines is displayed by two switching states on the output relay.
The sensor differentiates between the two switching states:
• Material flow
• Material blockage or standstill.
System
A complete measuring device consists of the sensor and a transmitter which powers the sensor and provides a switch output.
The control elements for the start-up procedure are found on the FlowJam A’s DIN rail electronics. Both the switching sensitivity
and the response delay can be set.
Electrical connection
A 2-core cable is required to connect the sensor to the transmitter.
The length must not exceed 300 m.
The sensor is equipped with an M12 connector (including a mating plug).
Technical Data
Sensor | Power supply | 12 V DC, powered by transmitter |
---|---|---|
Connection | M12 connector | |
Power consumption | approx. 1.5 W | |
Housing | Aluminium | |
Protection system | IP 65 | |
Process temperature | – 20 … + 60 °C | |
Ambient temperature | – 20 … + 60 °C | |
Required material speed | min. 0.1 m/s | |
Working frequency | K-Band 24.125 GHz; ± 100 MHz | |
Transmitting power | max. 5 mW | |
Dimensions | Housing: L 122 mm / W 39 mm / H 44 mm | |
Weight | Approx. 190 g | |
DIN rail transmitter | Power supply | 24 V DC ± 10 % |
Power consumption | approx. 3.5 W | |
Relay output – Voltage – Current – Capacity |
max. 110 V AC max. 1 A max. 60 W |
|
Fall-delay time | 1 … 15 s (continuously adjustable) | |
Weight | approx. 172 g |
Global Technology Systems
P.O. Box 799 Shalimar, FL 32579. USA
(850) 651-3388
[email protected]