Flow / no flow detection

FlowJam A Material Flow Monitor for Hose Lines

A microwave sensor that monitors solids conveyed through hose lines. The hose is inserted into the sensor, which signals material flow or a blockage on a relay output.

2–10 mmHose outer diameter (0.08 to 0.39 in)
0.1 m/sMin material speed (0.33 ft/s)
300 mMax cable length (984 ft)
IP 65Protection system
FlowJam A hose line flow monitor
  • For non-conducting hoses such as plastic or rubber
  • Hose outer diameters from 2 to 10 mm
  • The hose is inserted into the sensor
  • Detects solids of any type moving at 0.1 m/s or faster
  • Independent of flow direction
  • Adjustable switching sensitivity and response delay
  • Distinguishes material flow from blockage or standstill

Use

Where FlowJam A fits

FlowJam A monitors solids conveyed through hose lines. It is for non-conducting hoses, such as plastic or rubber, with external diameters of 2 to 10 mm. The hose is inserted into the sensor.

It detects solids of any type moving through the detection area at 0.1 m/s (0.33 ft/s) or faster. Detection does not depend on the flow direction, because it evaluates the Doppler effect.

The output relay shows one of two switching states:

  • Material flow
  • Material blockage or standstill
FlowJam A with a hose inserted
FlowJam A in use

System

Sensor and DIN rail transmitter

A complete device consists of the sensor and a DIN rail transmitter. The transmitter powers the sensor and provides the switch output.

The start-up controls are on the DIN rail electronics. Switching sensitivity and response delay are both adjustable, and the response time is continuously adjustable from 1 to 15 s.

The electrical connection is a 2-core cable with a maximum length of 300 m (984 ft). The sensor has an M12 connector, and the mating plug is included.

FlowJam A dimension drawing with DIN rail transmitter
Dimensions
FlowJam A electrical connection diagram
Electrical connection

Technical data

FlowJam A specifications

Imperial values are converted from the manufacturer's metric data. Confirm critical values against the product information PDF.

Sensor
Power supply12 V DC, powered by the transmitter
ConnectionM12 connector
Power consumptionApprox. 1.5 W
HousingAluminium
Protection systemIP 65
Process temperature−20 to +60 °C (−4 to +140 °F)
Ambient temperature−20 to +60 °C (−4 to +140 °F)
Required material speedMin. 0.1 m/s (0.33 ft/s)
Working frequencyK-band 24.125 GHz (±100 MHz)
Transmitting powerMax. 5 mW
DimensionsHousing: 122 × 39 × 44 mm L × W × H (4.8 × 1.5 × 1.7 in)
WeightApprox. 190 g (6.7 oz)
DIN rail transmitter
Power supply24 V DC ±10%
Power consumptionApprox. 3.5 W
Relay outputMax. 110 V AC, 1 A, 60 W
Fall-delay time1 to 15 s, continuously adjustable
WeightApprox. 172 g (6.1 oz)

Common questions

FlowJam A FAQ

What hoses does FlowJam A work with?

Non-conducting hoses, such as plastic or rubber, with external diameters of 2 to 10 mm. The hose is inserted into the sensor.

What does FlowJam A detect?

Solids of any type moving at 0.1 m/s (0.33 ft/s) or faster. The output relay shows either material flow or material blockage or standstill.

Does flow direction matter for FlowJam A?

No. Detection is independent of the flow direction, because the sensor evaluates the Doppler effect.

What does a complete FlowJam A system include?

The sensor and a DIN rail transmitter. The transmitter powers the sensor and provides the switch output.

What can be adjusted on FlowJam A?

Switching sensitivity and response delay. The response time is continuously adjustable from 1 to 15 s.

How far can the FlowJam A sensor be from the transmitter?

Up to 300 m (984 ft), over a 2-core cable.

Talk with GTS

Is FlowJam A right for your material?

Tell us what material is moving and the hose size. We'll confirm whether FlowJam A fits or recommend a better option.