Flow / no flow detection

FLOWguard K Inline Flow Monitor for Powders

An electrostatic flow monitor for powders in small hoses and pipes. It mounts between flanges, has no moving parts and never touches the material, and comes with a relay or a 4–20 mA output.

40 barMax process pressure (580 psi)
DN 10–100DIN flange sizes (ANSI ½ to 4 in)
4–20 mAK20 analog output; K01 relay
IP 67Degree of protection
FLOWguard K inline electrostatic flow monitor
  • Electrostatic (triboelectric) sensing
  • No moving parts and no contact with the material
  • Flow meter or monitor for powders in small hoses and pipes
  • Compact stainless steel construction
  • Relay (K01) and 4–20 mA (K20) versions
  • Flow indication on an LED bar (relay version)
  • Mounts between DIN or ANSI flanges rated to 40 bar (580 psi)
  • Detects moving material only, with no influence from deposits
  • Reliable, long-term stable and maintenance-free

Use

Where FLOWguard K fits

FLOWguard K monitors mass flow in pneumatic lines, feeders and gravity chutes, at flow rates from grams per hour to tonnes per hour.

It senses the electrical charges that particles pick up through friction with surfaces such as the pipe wall. Build-up on the wall is not detected.

Function

How the electrostatic measurement works

FLOWguard K uses the electrostatic principle, also known as the triboelectric effect. Charged particles passing the sensor induce a signal against the grounded transport channel. The current noise in that signal rises with particle concentration and transport speed, and the electronics scale it to a mass throughput or concentration reading. Adjustment is manual.

Because only moving charges produce a signal, caking and deposits have no effect.

Products that form an electrically conductive layer on the sensor cannot be measured.

FLOWguard K electrostatic measuring principle
Measuring principle

Mounting and installation

Installation requirements

  • Install according to local guidelines and keep the IP rating intact.
  • Ground the device.
  • Provide thermal isolation for process temperatures above 80 °C (176 °F).
  • Shade the device from direct sun.
  • Provide heating below −20 °C (−4 °F).
  • Avoid vibration.
  • Open the device only when it is de-energized.

Technical data

FLOWguard K specifications

Transcribed from the product brochure, with converted units added. Confirm critical values against the brochure PDF.

Electrical
Supply voltageK01/K02: 17 to 31 V DCK20: 17 to 31 V DC, max. 90 mA
Relay output (K01)Max. 48 V AC/DC, 1 A
Transistor output (K02)Galvanically isolated, max. 31 V DC, 15 mA
Analog output (K20)4–20 mA, galvanically isolated, load < 500 Ω
SwitchingHigh / low switchable
DampingK01/K02: 0 to 10 sK20: 0 to 180 s
Switch point (K01/K02)1 to 10
Zero set (K20)4 mA
Sensitivity adjustment1 to 180,000
Process
Measurable mass flowFrom g/h to t/h
Process temperatureMax. 90 °C (194 °F)
Ambient temperature−20 to +70 °C (−4 to +158 °F)
Process pressureMax. 40 bar (580 psi)
Nominal pressurePN 10, 16, 25 or 40
Degree of protectionIP 67 (EN 60529)
EMCEN 61326-1
Ex optionZone 2 and/or 22: II 3G EEx nA II T4 / II 3D IP67 T100°C
Materials and sizes
InsulationPolyamide (PA), 2 mm
Connector headStainless steel 1.4305 (AISI 303)
Process couplingStainless steel 1.4571 (AISI 316Ti)
DIN flange sizesDN 10, 15, 20, 25, 32, 40, 50, 65, 80, 100
ANSI flange sizes½ in to 4 in
HousingØ 89 mm (3.5 in), width 85 mm (3.35 in)
Overall height195 to 340 mm (7.68 to 13.39 in), depending on size
Electrical connectionM16 × 1.5 screw connectors
FLOWguard K technical data sheet
FLOWguard K technical data

Application examples

FLOWguard K in real processes

FLOWguard K in a shot blasting application
Shot blasting
FLOWguard K installation photo
FLOWguard K with and without a wear inlet
Wear inletFLOWguard K with and without a wear inlet

Common questions

FLOWguard K FAQ

How does FLOWguard K measure flow?

It uses the electrostatic principle. Charged particles passing the sensor induce a signal whose noise rises with particle concentration and velocity, and the electronics convert that into a mass throughput or concentration reading.

What is FLOWguard K used for?

Monitoring powder flow in small hoses and pipes, in pneumatic lines, feeders and gravity chutes, at flow rates from grams per hour to tonnes per hour.

How is FLOWguard K installed?

It mounts between DIN or ANSI flanges rated to 40 bar (580 psi). DIN sizes run from DN 10 to DN 100 and ANSI sizes from ½ in to 4 in.

What outputs does FLOWguard K have?

The K01 has a relay output with an LED bar for flow indication, the K02 has a transistor output, and the K20 has a galvanically isolated 4–20 mA output.

Does build-up on the pipe wall affect FLOWguard K?

No. Only moving charged particles produce a signal, so caking and deposits have no effect.

What can FLOWguard K not measure?

Products that form an electrically conductive layer on the sensor.

Talk with GTS

Is FLOWguard K right for your material?

Tell us what powder you're conveying, the line size and the pressure. We'll confirm whether FLOWguard K fits or recommend a better option.