Solids flow meters
DensFlow Dense-Phase Flow Meter
A measuring system for continuous flow metering of powders and granules in pneumatic dense-phase conveying and at high throughput, with an open measuring tube and no mechanics.

- Reliable flow metering in pneumatic dense-phase conveying
- Unlimited throughput volumes can be measured
- Optionally pressure-resistant up to 25 bar (363 psi)
- No obstruction in the cross-section, so no dead spots where residue can form
- Measurement is independent of the flow speed of the material
- Simple retrofitting
- Maintenance-free
- Contact-free measuring method with no mechanics
Use
Where DensFlow fits
DensFlow is a measuring system developed specifically for flow metering of solids in dense-phase conveying. It is used for online measurement of:
- Powders or granules
- In pneumatic dense-phase transport

Function
How concentration and speed are measured
A high-frequency electromagnetic alternating field is coupled in to generate a homogeneous measuring field in the measuring pipe. Solids within this field reduce its amplitude, giving a measuring signal that corresponds to the concentration of the solids being conveyed in the measuring tube (kg/m³).
Using the same kind of sensor, the change in the alternating field is measured at two additional points in the measuring tube. These two sensors are a defined distance apart.
The analysis electronics, with an integrated correlator, determine from the two sensor signals how long the material takes to travel between the sensors. The known distance is then used to work out the speed of the solids (m/s).
From the two measured parameters, concentration (K) and speed (v), and the known cross-section (A) of the measuring tube, the flow is determined as:
Q = K × v × A
It is output as a 4–20 mA signal.

Mounting and installation
Flange installation in the conveying line
In pneumatic dense-phase conveying, the installation point is specified according to the conveying inlet and outlet paths.
The measuring tube is installed at the specified point with a flange connection. Measuring tubes are supplied as standard in nominal widths up to 150 mm (5.9 in) with flange connections in accordance with DIN 2576.

Technical data
DensFlow specifications
Imperial values are converted from the manufacturer's metric data. Confirm critical values against the product information PDF.
| Housing | Stainless steel 1.4571 (316Ti), NW 10 to 125 mm (0.4 to 4.9 in), flange EN 1092-1 |
|---|---|
| Inner pipe | Ceramic |
| Protection category | IP 65 according to EN 60529/10.91 |
| Environment temperature | Sensor pipe electronics: −20 to +60 °C (−4 to +140 °F)Sensor pipe: −20 to +80 °C (−4 to +176 °F); higher temperatures as an option |
| Max. working pressure | 16 bar (232 psi), optional 25 bar (363 psi) |
| Working frequency | 100 kHz |
| Weight | Depending on the nominal diameter |
| Velocity range | 1 to 10 m/s (3.3 to 32.8 ft/s) |
| Accuracy | ±2–5% in the calibrated range |
| Dimensions | NW + 90 mm, L 500 mm (19.7 in) |
| Power supply | 110/240 V, 50 Hz; 24 V DC |
|---|---|
| Power consumption | 20 W / 24 VA |
| Protection category | IP 65 to EN 60529/10.91 |
| Operating temperature | −10 to +45 °C (+14 to +113 °F) |
| Dimensions | 258 × 237 × 174 mm W × H × D (10.2 × 9.3 × 6.9 in) |
| Weight | Approx. 2.5 kg (5.5 lb) |
| Cable glands | 3 × M16 (4.5–10 mm Ø) |
| Terminal clamp wire size | 0.2–2.5 mm² (AWG 24–14) |
| Current output signal | 2 × 4–20 mA (0–20 mA), load < 500 Ω |
| Alarm output / error output | Relay with toggle switch, max. 250 V AC, 1 A |
| Data backup | Flash memory |
| Impulse output | Open collector, max. 30 V, 20 mA |
| RS 485 interface | Modbus |
Application examples
DensFlow in real processes




Common questions
DensFlow FAQ
What is DensFlow used for?
Continuous flow metering of powders or granules in pneumatic dense-phase conveying, including at high throughput.
How does DensFlow determine the flow?
It measures the concentration of solids in the measuring tube from the damping of a high-frequency electromagnetic alternating field, and the speed of the solids by correlating the signals from two sensors a defined distance apart. Flow is Q = K × v × A, output as a 4–20 mA signal.
Does DensFlow obstruct the conveying line?
No. The installation creates no obstruction in the cross-section, so there are no dead spots where residue can form.
What pressure can DensFlow handle?
16 bar (232 psi) as standard, and optionally up to 25 bar (363 psi).
What pipe sizes is DensFlow available in?
Measuring tubes are supplied as standard in nominal widths up to 150 mm (5.9 in) with flange connections in accordance with DIN 2576.
How accurate is DensFlow?
±2–5% in the calibrated range.
Talk with GTS
Is DensFlow right for your material?
Tell us what you're conveying, the line size and the conveying pressure. We'll confirm whether DensFlow fits or recommend a better measurement principle.