Solids flow meters

Dchute Chute Scale for Bulk Solids

A chute scale that combines contact-free speed measurement with proven weighing technology to determine the mass throughput of free-flowing bulk materials, for throughputs from 500 lbs/hr to 50 t/h.

50 t/hMax throughput
500 lbs/hrMin throughput
0.2%Accuracy up to, of final value
NoneCalibration required
Dchute chute scale for bulk solids
  • High precision
  • Largely independent of bulk material properties
  • No moving parts
  • Flexible adaptation
  • Free flow, even when the device is switched off
  • Easy to integrate
  • Works without calibration
  • Maintenance-free

Use

Where Dchute fits

Dchute is a chute scale that combines speed measurement with proven weighing technology to determine the mass throughput of free-flowing bulk materials with high precision.

In the robust controller, the two absolute measured values, weight and speed, are used to calculate throughput without calibration. The result is output in analog or digital form.

Function

Weight and speed, measured separately

An integrator and a dosing function allow batch weighing (kg) as well as continuous dosing (kg/h).

In a variation of the method used in belt scales, the weight of the bulk material flow on a chute segment is determined continuously by weighing technology, while the sliding speed of that mass is measured without contact. The mass throughput is calculated from these two absolute, calibration-free values.

Because weight and speed are measured separately, neither changing product properties nor changing process conditions affect the result.

Mounting and installation

Installation

The diagram shows how the Dchute is installed in the process.

Dchute installation diagram
Dchute installation

Technical data

Dchute specifications

Transcribed from the product brochure, with converted units added. Confirm critical values against the brochure PDF.

Dchute, size 250
Measurement range0.2 to 20 t/h / 0.4 to 35 m³/h; other sizes on request
AccuracyUp to 0.2% of the final value
MaterialStainless steel 1.4301, ceramic (plate)
Compression strength0.1 bar (1.45 psi)
Purge air connectionFor very dusty products, 2 bar (29 psi) / 0.6 Nm³/h
Protection classIP 64
TemperatureProcess: 10 to 40 °C (50 to 104 °F)Ambient: 0 to 50 °C (32 to 122 °F)
InstallationVertical, vibration-free
System controller D-con
InterfacesRS 485, Ethernet, CAN bus
Outputs3 × relay, 2 × analog (4–20 mA)
Inputs1 × digital, 1 × analog
Connection cableDigital, max. length 1000 m (3,280 ft)
Dchute technical data sheet
Dchute technical data

Common questions

Dchute FAQ

How does the Dchute measure mass throughput?

The weight of the material on a chute segment is determined continuously by weighing technology while its sliding speed is measured without contact. Throughput is calculated from those two absolute values.

Does the Dchute need calibration?

No. Weight and speed are both absolute values, so throughput is calculated without calibration.

What throughput range does the Dchute cover?

Throughputs from 500 lbs/hr to 50 t/h.

Is the Dchute affected by changing product properties?

No. Because weight and speed are measured separately, neither changing product properties nor changing process conditions affect the result.

Can the Dchute be used for batching?

Yes. An integrator and a dosing function allow batch weighing in kg as well as continuous dosing in kg/h.

Does material still flow if the Dchute is switched off?

Yes. Material flows freely even when the device is switched off, and there are no moving parts.

Talk with GTS

Is Dchute right for your material?

Tell us what you're conveying, the pipe size and how it moves. We'll confirm whether Dchute fits or recommend a better measurement principle.