Solids flow meters
Dchute Chute Scale for Bulk Solids
A chute scale that combines contact-free speed measurement with proven weighing technology to determine the mass throughput of free-flowing bulk materials, for throughputs from 500 lbs/hr to 50 t/h.

- High precision
- Largely independent of bulk material properties
- No moving parts
- Flexible adaptation
- Free flow, even when the device is switched off
- Easy to integrate
- Works without calibration
- Maintenance-free
Use
Where Dchute fits
Dchute is a chute scale that combines speed measurement with proven weighing technology to determine the mass throughput of free-flowing bulk materials with high precision.
In the robust controller, the two absolute measured values, weight and speed, are used to calculate throughput without calibration. The result is output in analog or digital form.
Function
Weight and speed, measured separately
An integrator and a dosing function allow batch weighing (kg) as well as continuous dosing (kg/h).
In a variation of the method used in belt scales, the weight of the bulk material flow on a chute segment is determined continuously by weighing technology, while the sliding speed of that mass is measured without contact. The mass throughput is calculated from these two absolute, calibration-free values.
Because weight and speed are measured separately, neither changing product properties nor changing process conditions affect the result.
Mounting and installation
Installation
The diagram shows how the Dchute is installed in the process.

Technical data
Dchute specifications
Transcribed from the product brochure, with converted units added. Confirm critical values against the brochure PDF.
| Measurement range | 0.2 to 20 t/h / 0.4 to 35 m³/h; other sizes on request |
|---|---|
| Accuracy | Up to 0.2% of the final value |
| Material | Stainless steel 1.4301, ceramic (plate) |
| Compression strength | 0.1 bar (1.45 psi) |
| Purge air connection | For very dusty products, 2 bar (29 psi) / 0.6 Nm³/h |
| Protection class | IP 64 |
| Temperature | Process: 10 to 40 °C (50 to 104 °F)Ambient: 0 to 50 °C (32 to 122 °F) |
| Installation | Vertical, vibration-free |
| Interfaces | RS 485, Ethernet, CAN bus |
|---|---|
| Outputs | 3 × relay, 2 × analog (4–20 mA) |
| Inputs | 1 × digital, 1 × analog |
| Connection cable | Digital, max. length 1000 m (3,280 ft) |

Common questions
Dchute FAQ
How does the Dchute measure mass throughput?
The weight of the material on a chute segment is determined continuously by weighing technology while its sliding speed is measured without contact. Throughput is calculated from those two absolute values.
Does the Dchute need calibration?
No. Weight and speed are both absolute values, so throughput is calculated without calibration.
What throughput range does the Dchute cover?
Throughputs from 500 lbs/hr to 50 t/h.
Is the Dchute affected by changing product properties?
No. Because weight and speed are measured separately, neither changing product properties nor changing process conditions affect the result.
Can the Dchute be used for batching?
Yes. An integrator and a dosing function allow batch weighing in kg as well as continuous dosing in kg/h.
Does material still flow if the Dchute is switched off?
Yes. Material flows freely even when the device is switched off, and there are no moving parts.
Talk with GTS
Is Dchute right for your material?
Tell us what you're conveying, the pipe size and how it moves. We'll confirm whether Dchute fits or recommend a better measurement principle.