DensFlow –
Flow metering in dense-stream
- Reliable flow metering in pneumatic dense-stream
- Unlimited throughput volumes can be measured
- optionally pressure-resistant up to 25 bar
- Installation creates no obstacle in the profile, hence no dead spots in which residue can form
- Measurement independent of the flow speed of the material
- Simple retrofitting
- Maintenance-free
- Contactless measuring procedure (no mechanics)

What do you want to do?
Use
– Powders or granules
– in pneumatic dense-stream transport
Function
Using the same kind of sensor, the change of the alternating field is measured within the measuring tube at two additional points. These two sensors have a defined distance to each other.
The analysis electronics with its integrated correlator determines the runtime of the conveyor belt between the both sensors from the two sensor signals. The known distance is then used to determine the speed of the solid (m/sec).
The two measured parameters concentration (K) and speed (v) as well as the known profile (A) of the measuring tube, the flow is determined as
Q = K x v x A
and output as a 4 … 20 mA signal.
Mounting and Installation
The assembly of the measuring tube at the specified installation point takes place using a flange installation. Measuring tubes can be supplied in standard form in nominal widths of up to 150 mm with flange connections in accordance with DIN 2576.
Technical Data
Sensor | Housing | Stainless Steel 1.4571, NW 10 … 125 mm, flange EN 1092-1 | |
---|---|---|---|
Inner pipe | Ceramic | ||
Protection category | IP 65 according EN 60 529/10.91 | ||
Environment temperature | Sensor pipe electronic: – 20 … + 60 °C Sensor pipe: – 20 … + 80 °C (higher temperatures as option) |
||
Max. working pressure | 16 bar, optional 25 bar | ||
Working frequency | 100 kHz | ||
Weight | Depending on the nominal diameter | ||
Velocity range | 1 … 10 m/s | ||
Accuracy | ± 2 … 5 % in the calibrated range range | ||
Dimension | NW + 90 mm, L 500 mm | ||
Transmitter | Power supply | 110 / 240 V, 50 Hz, 24 V DC | |
Power consumption | 20 W / 24 VA | ||
Protection category | IP 65 to EN 60 529 / 10.91 | ||
Operating temperature | – 10… + 45 °C [14 … 113 °F] | ||
Dimensions | 258 x 237 x 174 (W x H x D) | ||
Weight | approx. 2.5 kg | ||
Cable glands | 3 x M 16 (4.5 – 10 mm Ø) | ||
Terminal clamp wire size | 0.2 – 2.5 mm² [AWG 24-14] | ||
Current output signal | 2 x 4 … 20 mA (0 … 20 mA), load < 500 | ||
Alarm output – Error output | Relay with toggle switch – max. 250 V AC, 1 A | ||
Data backup | Flash memory | ||
Impulse output | Open Collector – max. 30 V, 20 mA | ||
RS 485 interface | ModBus | ||
Application Examples

in dense streams in steel manufacture

in dense streams in a steel plant

during coal injection in the steel plant

in the steel plant during the firing of the oven
Global Technology Systems
P.O. Box 799 Shalimar, FL 32579. USA
(850) 651-3388
Info@onthelevel.com