Dust emission monitoring

ProSens Dust Concentration Monitor

A sensor developed for reliable dust measurement on the clean side after filters. It outputs a trend signal or, after calibration, an absolute dust concentration, including in large channel diameters and at high temperatures.

0.1 mg/m³Measurement range from
150 °CStandard process temperature (302 °F)
25 barMax pressure, optional (363 psi)
ATEXCategory 1/2 GD
ProSens dust concentration sensor
  • Dust measurement in large channel diameters too
  • Outputs dust concentration as an absolute value
  • ATEX-certified
  • Measures dust concentration at high temperatures
  • Trend signal or absolute value

Use

Where ProSens fits

ProSens is meant for dust measurement on the clean side after filters. It outputs either a trend signal or, after calibration, absolute values for emission measurement. Absolute output is what you need when the concentration has to be stated in mg/m³.

It is built for exact measurement in large channel diameters and at high temperatures, and it is ATEX-certified for GasEx Zone 1 and DustEx Zone 20.

ProSens output diagram
Trend and absolute output
ProSens installed after a filter
ProSens after a filter

Function

How ProSens measures dust

ProSens works on the triboelectric effect. For a constant dust, the signal is proportional to the dust concentration, even when dust deposits form on the probe. The method is precise and needs little maintenance.

System

A complete system has three components: a welded casing that receives the sensor, the ProSens sensor, and the PME 100 transmitter. The transmitter comes in a field housing with a touch-panel display or as a DIN rail version. The DIN rail version includes parameter-setting software.

ProSens system with sensor and transmitter
System overview
ProSens measuring principle
Measuring principle

Mounting and installation

Fitting the sensor in the channel

ProSens mounts in metal channels and pipelines, away from bends and inserts such as flaps and valves.

  • Keep the sensor rod at least 3 × the channel diameter from inserts, in every flow direction.
  • Non-metallic channels need metal sheathing (a sleeve, foil or close-mesh grid) over a length of at least 5 × the channel diameter.
  • Drill a hole in the channel wall, weld the casing in flush and vertical to the channel, insert the rod and secure it with the fixing screw.
  • The rod should be one third to two thirds of the channel diameter. It can be shortened to the right length, down to 70 mm (2.8 in).
ProSens mounted in a channel
ProSens mounting

Technical data

ProSens specifications

Imperial values are converted from the manufacturer's metric data. Confirm critical values against the product information PDF.

Sensor
Measurement rangeFrom 0.1 mg/m³
Process temperatureStandard: 150 °C (302 °F); higher temperatures on request
PressureMax. 2 bar (29 psi)Optional: up to 25 bar (363 psi)
Flow speedMin. 4 m/s (13 ft/s)
Humidity95% relative humidity or less (non-condensing)
Measuring principleTriboelectric effect
Ambient temperature−20 to +60 °C (−4 to +140 °F)
Sensor rodStainless steel; length 500 or 1,000 mm (19.7 or 39.4 in)
HousingAluminium
Protection typeIP 66; ATEX category 1/2 GD
Electric connectionConnection room DIN M 20
WeightApprox. 1.5 kg (3.3 lb)
Transmitter (DIN rail)
Power supply24 V DC ±10%
Power consumption20 W / 24 VA
Protection typeIP 40 to EN 60529
Ambient operating temperature−10 to +45 °C (+14 to +113 °F)
Dimensions23 × 90 × 118 mm W × H × D (0.9 × 3.5 × 4.6 in)
WeightApprox. 172 g (6.1 oz)
Terminal conductor cross-section0.2–2.5 mm² (AWG 24–14)
Current output signal4–20 mA, load 500 Ω
Switch output, measurement alarmRelay with switchover contact, max. 250 V AC, 1 A
InterfaceModbus RTU (RS 485)
Data backupFlash memory

Application examples

ProSens in real processes

ProSens detecting metal dust after a bag filter
Metal dustDetection on the clean-gas side after a bag filter
ProSens measuring filter dust in a clean-gas path
Filter dustQuantity measurement in clean-gas paths
ProSens detecting lime dust
LimeLime detection
ProSens detecting dust in an Ex zone
Ex zoneDust detection in an Ex zone

Common questions

ProSens FAQ

What is ProSens used for?

Dust measurement on the clean side after filters, including in large channel diameters and at high temperatures.

Does ProSens give a trend or an absolute value?

Either. It outputs a trend signal or, after calibration, an absolute dust concentration in mg/m³ for emission measurement.

How does ProSens work?

On the triboelectric effect. For a constant dust the signal is proportional to dust concentration, even when deposits form on the probe.

What does a complete ProSens system include?

A welded casing that receives the sensor, the ProSens sensor and the PME 100 transmitter, in a field housing with touch-panel display or as a DIN rail version.

Is ProSens approved for explosion-hazard zones?

Yes. It is ATEX-certified, category 1/2 GD, for GasEx Zone 1 and DustEx Zone 20.

How long should the ProSens rod be?

One third to two thirds of the channel diameter. Rods come in 500 or 1,000 mm lengths and can be shortened down to 70 mm (2.8 in).

Talk with GTS

Is ProSens right for your duct?

Tell us what dust you're filtering, the duct size and the gas temperature. We'll confirm whether ProSens fits or recommend a better option.