Solids Measurement & Control

Dry Bulk Solids Mass Flow Measurement

Continuous, non-contact mass flow measurement for dust, powder, and granular solids in free fall, pneumatic conveying, and gravity lines — built for plants that can't afford to run on estimates.

Request a Quote See the Product Lineup
Since 1994 ATEX-rated options Retrofit-friendly sensors (850) 651-3388

The Problem: You Can't Control What You Can't Measure

Batch weighers, mechanical feeders, and manual sampling all break down the same way: they're slow, they're intermittent, and they tell you what happened five minutes ago instead of what's happening right now. In dry bulk handling — cement raw meal, lime, coal dust, grain, plastic pellets, sugar, fertilizer — that lag shows up as over-dosing, off-spec blends, unbilled product loss, and operators chasing a moving target with a control loop that's always a step behind.

On The Level (Global Technology Systems) has built mass flow instrumentation into industrial solids lines since 1994. Our meters give you a continuous, real-time signal — not a snapshot — so dosing, blending, and inventory control loops can actually close.

How Mass Flow Measurement Works

There's no single technology that covers every pipe, pressure, and material — that's why the product line splits by conveying regime and installation constraint rather than a one-size sensor:

Microwave / Electromagnetic Sensing

A high-frequency field is coupled into a metal pipe or a ceramic-lined measuring tube. Particles passing through the field either reflect microwave energy (counted like a particle counter) or dampen the field's amplitude in proportion to solids concentration. Combined with a velocity measurement, the system solves Q = K (concentration) × v (velocity) × A (cross-section) continuously.

Radiometric Sensing

For opaque, abrasive, or hard-to-access lines where a contact or in-line sensor isn't practical, a radiometric source and detector mounted outside the pipe read bulk density and, combined with velocity, derive mass flow without touching the product stream at all.

Suitable Materials

  • Cement raw meal, clinker dust, and lime
  • Coal, coke, and biomass dust or pellets
  • Grain, flour, starch, and other food powders
  • Salt, sugar, and mineral powders
  • Plastic pellets and resins
  • Fertilizer granules and chemical powders

Particle sizes from roughly 1 nanometer up to 1 cm have been successfully metered across the product line, depending on the sensor selected.

Industries and Applications

Cement & Building Materials

Raw meal dosing, additive admixture, and pneumatic transport metering.

Power & Waste-to-Energy

Activated carbon and hearth furnace coke dosing for pollutant bonding.

Food & Agriculture

Spice dosing, grain metering, baking powder and starch throughput.

Chemical & Fertilizer

Powder and granule dosing on pneumatic and gravity lines.

Steel & Metals

Pulverized coal and lime injection metering.

Plastics & Resin

Pellet throughput on conveying and free-fall lines.

Installation Requirements

Every meter in this family is designed to retrofit into an existing metal pipe rather than force a redesign of your conveying line:

  • In-line sensors (SolidFlow) mount through a welded socket and a drilled bore — no cutting the pipe, no flanges required on smaller lines.
  • Fall-through sensors (MaxxFlow HTC) install after a mechanical feed point — screw conveyor, rotary valve, air slide, bucket elevator — with a minimum inlet run and are available in DN 100/150/200.
  • Pipe diameters over 200 mm typically use two or three sensors spaced 90° or 120° apart for representative sampling.
  • Free-fall applications generally want at least 300 mm of fall height ahead of the sensor.
  • Calibration happens in place — push a button, enter a known reference quantity, done.

Available Products

Microwave / In-Line

SolidFlow 2.0

Free-fall and pneumatic mass flow sensor with active roping compensation. Up to 20 t/h. ATEX-certified.

View SolidFlow →
Ceramic Fall-Through

MaxxFlow HTC

High-volume fall-through meter for the outlet of screw conveyors, rotary valves, and air slides. No practical upper flow limit, up to 10 bar.

View MaxxFlow HTC →
Dense-Phase

DensFlow

Continuous flow metering purpose-built for pneumatic dense-stream conveying, pressure-rated up to 25 bar.

View DensFlow →
Radiometric

Drad

Non-contact radiometric flow measurement for opaque or hard-to-instrument lines.

View Drad →
Weigh-Based

Dmass / DScale

Impact-plate and chute-based mass flow measurement for gravity-fed applications.

View Dmass →
Multi-Sensor

MultiFLOW Meter

Combined sensing platform for facilities running multiple measuring points off a shared transmitter architecture.

View MultiFLOW →

Metering a specific conveying regime? Go straight to Dilute/Lean Phase Flow Measurement or Dense Phase Flow Measurement for the sensor best suited to that line.

Typical Measurement Ranges and Accuracy

ProductPrincipleRange / RatingAccuracy
SolidFlow 2.0MicrowaveUp to 20 t/h, 1 bar (10 bar optional)±2–5% in calibrated range
MaxxFlow HTCElectromagnetic / ceramicNo fixed upper limit, up to 10 bar, up to 120°C±3% (end of range, calibrated material)
DensFlowElectromagnetic (dense-phase)Velocity range 1–10 m/s, up to 25 bar±2–5% in calibrated range

Accuracy is always stated for a specific calibrated material and range — bulk density variation, moisture, and particle-size distribution all move the number. We calibrate on your material, not a generic reference powder.

Advantages and Limitations

Advantages

  • Continuous, real-time signal instead of periodic sampling
  • No moving parts on most sensors — low maintenance
  • Retrofits into existing metal pipe without a line redesign
  • Works across dust, powder, and granular material types

Limitations

  • Products that leave an electrically conductive coating on the pipe wall (via caking or abrasion) can interfere with electromagnetic-principle sensors
  • Accuracy is calibration-dependent — a meter calibrated on one material shouldn't be assumed accurate on another without recalibration
  • Radiometric options carry regulatory and licensing requirements around the source

Product Selection Guidance

If your line is…Start with
Free-fall after a screw conveyor or rotary valve, moderate throughputSolidFlow 2.0
High-volume fall-through, no hard upper flow limit neededMaxxFlow HTC
Pneumatic dense-phase conveying at pressureDensFlow
Opaque, abrasive, or inaccessible for in-line sensor mountingDrad (radiometric)
Gravity-fed chute or impact applicationDmass / DScale

Not sure which column fits? Send us your pipe size, material, conveying method, and target accuracy through the form below — we'll recommend the sensor, not just sell you the one on the page you landed on.

Frequently Asked Engineering Questions

Do these meters require the line to be shut down for installation?

SolidFlow and similar in-line sensors mount through a welded socket with a drilled bore — installation is a hot-work job on the pipe but doesn't require rerouting or replacing the line. Fall-through meters like MaxxFlow HTC install at an existing transition point in the conveying path.

Can one sensor handle both free-fall and pneumatic conveying?

SolidFlow 2.0 is validated for both. MaxxFlow HTC and DensFlow are matched to specific regimes — fall-through and dense-phase pneumatic, respectively — because the velocity profile and pressure rating differ enough to need a purpose-built sensor.

How is the meter calibrated?

Calibration is done in the installed state: run a known reference quantity through the line and enter it at the transmitter. Recalibrate if you change materials significantly.

What outputs do these meters provide for integration with our control system?

Standard output is 4–20 mA current with Modbus over RS-485 available on the product line, plus pulse and relay/alarm outputs depending on model.

Related Case Studies

Waste-to-Energy

Hearth Furnace Coke Metering

Continuous flow metering of hearth furnace coke for pollutant bonding in a waste incineration plant.

Cement

Raw Meal Mass Flow

MaxxFlow HTC deployed after air slide and dosing roller stages for raw meal throughput control.

Steel

Pulverized Coal Injection

DensFlow monitoring dense-stream coal dust delivery to individual injection lances in a steel plant.

Request a Quote

Tell us about your line and we'll recommend the right meter — no generic spec sheet, an actual answer from someone who's sized these before.

Global Technology Systems / On The Level · PO Box 799, Shalimar, FL 32579 · (850) 651-3388 · Info@onthelevel.com